DTUS1710

Clinical DENTAL TRIBUNE | July 201010A By Dov M. Almog, DMD, Odalys Hector, DMD, Samuel Melcer, DMD and Kenneth Cheng, DDS Implant fracture: A look at the physical mechanisms for failure The etiology and physical mecha- nism of fractured dental implants phenomenon have been reviewed and studied at length in recent years.1–8 For the most part, the stud- ies concluded that the crown-to-root ratio guidelines associated with nat- ural teeth should not be applied to a crown-to-implant restorations ratio. According to these studies, the crown-to-implant ratios of those implants that were considered suc- cessful at the time the reviews took place were similar to those implants that failed. Apparently, according to some of these studies, the guidelines that are used by some clinicians to estab- lish the future prognosis of implant- supported restorations are usually empirical and lack scientific valida- tion as far as the possible causes for implant fractures. However, as oral implantology has been the fastest growing seg- ment in dentistry, the gaining of insight into these failure processes, including the accurate understand- ing of critical anatomical, restorative and mechanical information, might stimulate the clinicians’ implemen- tation of preventive action that may avoid the future fractures outcome with dental implants. Case report A 72-year-old Caucasian male recently presented to our clin- ic. Consistent with the patient’s chief complaint, a comprehensive oral and maxillofacial examina- tion, including full-mouth X-rays, revealed, among other things, two fractured endosseous implants #6 and #7 (Fig. 1). These 3.3 mm x 15 mm implants (Lifecore Biomedical, Chaska, Minn.) were placed and restored in 2003. The implants were placed as per protocol, utilizing a surgical template consisting of two guiding sleeves (DePlaque, Victor, N.Y.). The implants were allowed to integrate for six months. No surgi- cal complications were noted dur- ing this time. At the conclusion of the six-month waiting period, the implants were uncovered in the nor- mal manner and healing abutments placed. The implants were subsequent- ly restored with implant-support- ed crowns that were functional for approximately six years until the implants fractured. While this treatment option was developed with an appreciation of the patient’s occlusal and mechani- cal circumstances and habits, fol- lowing the implants’ fracture, a retrospective analysis of the site planned for the implants revealed extended inter-occlusal space on the articulated models and widespread occlusal wear of the opposing denti- tion (Fig. 2). When the patient presented recently to our clinic, the only por- tion of the restoration that was still present in his mouth was abutment #6, which was still connected to one of the fractured implants, and was removed with a hex driver (Fig. 3). Proceeding with careful assess- ment of all the available retrospec- tive diagnostic information and upon further discussion with the patient, several diagnostic assump- tions and one follow-up treatment option were established that includ- ed replacement of the implant-sup- ported crowns by a removable cast partial denture. Considering the need for the removal of fractured implants must be balanced against the risk of increasing damage, a decision was made to remove the remaining abutment and the fractured piece of implant #6 allowing for primary closure of the soft tissue over the remaining implant bodies #6 and #7, i.e., “put them to sleep” (Fig. 4). This was followed by insertion of an immediate acrylic removable partial denture, and subsequently, a cast partial denture will be fabricated. This report attempts to provide an argument in favor of the con- sideration of physical mechanisms as potential contributors to implant fractures. While controversy continues to exist as to whether crown-to-root ratio can serve as an independent aid in predicting the prognosis of teeth,9 the same certainly applies to crown-to-implant ratio, unless multiple other clinical indices such as opposing occlusion, presence of parafunctional habits and material electrochemical problems, just to name a few, are considered. Implant fractures are considered one potential problem with dental implants, especially delayed frac- ture of titanium dental implants due to chemical corrosion and metal fatigue.2 Following careful review of the referenced articles, which are very enlightening, we realized that to a great extent they support our the- ory that there are multiple factors involved in implant fractures. These factors include magnitude, location, frequency, direction and duration of compressive, tensile and shear stresses; gender; implant location in the jaw; type of bone surrounding the implant; pivot/ful- crum point in relation to abutment connection; implant design; internal structure of the implant; length of time in the oral environment as it relates to metallurgic changes induced in titanium over time; gin- gival health and crown-to-implant- ratio. Considering the multiple factors involved in implant fractures, both physical and biological, we can only assume that it can happen especial- ly if the forces of the opposing occlu- sion and/or parafunctional habits are greater than the strength of the implant, especially over time. Therefore, it is imperative that the clinician be knowledgeable about the diversity of factors before recommending dental implants. Errors in diagnosing potential con- Figs. 1A, B: Implants #6 and #7 (Lifecore Biomedical, 3.3 mm x 15 mm) before (A) and after the fracture (B). Figs. 2A, B: Retrospective analysis of the site planned for the implants #6 and #7 (A) revealed an extended overbite, requiring long crowns (B) to meet esthetic needs, and at the same time, the opposing occlu- sion presented extensive occlusal wear. Figs. 3A, B: By default, based on physical principles, once an implant has integrated in the bone, the weakest point is the fulcrum where the internal screw engages the implant (A). Note the fracture level in implant #7 and fracture line in implant #6 (B).

Please activate JavaScript!
Please install Adobe Flash Player, click here for download